Knowledge Base Article

DWX-52D 5-Axis Dental Milling Machine

Title
There Is a Line of Level Difference in the Milling Results
Summary
There Is a Line of Level Difference in the Milling Results
Details
Is the machine out of correction?
The origin point may become out of position due to prolonged use or relocating the machine, which can result in a line of level difference. Perform automatic correction. If the expected results cannot be obtained even after performing automatic correction, perform manual correction. With manual correction, changing the Y value in Origin point may improve the situation. User's Manual Page 53

Are the CAM milling conditions correct?
Depending on the milling conditions, a line of level difference may occur. Review the CAM milling conditions.
Modified
April 28, 2020