Base de conocimientos Article
DWX-53D DWX-53D Dry Milling Machine
Cargo
DWX-53DC - 101D-00**The % milling bur cannot be released
Síntoma
DWX-53DC - 101D-00**The % milling bur cannot be released
Solución
101D-00**The % milling bur cannot be released.
% indicates a milling bur stocker number from 1 to 16 or 0.
| The returning of the milling bur failed. The inside of the collet or the ATC magazine might be dirty. |
- Hold down the touch sensor on the built-in panel.
This will clear the error. - Carry out Forced tool release in VPanel.
The collet will open. - Remove the milling bur.
- Clean the ATC magazine.
Cleaning after Milling Finishes
|
The collet and milling bur are affixed together and cannot be separated. The inside of the collet might be dirty. |
Retightening the Collet
|
The milling bur may not have been removed from the spindle unit after Forced tool release was executed. Be sure to remove the milling bur before cleaning the ATC magazine. |
|
The collet may be deformed. In this case, replace the collet. |
Modificado