Base de conocimientos Article
DWX-4 4-Axis Dental Milling Machine
Cargo
"101F-000*" The % milling bur chucking has slipped out
Síntoma
"101F-000*" The % milling bur chucking has slipped out.
The milling bur stocker number (1 to 7) is displayed for %
Solución
Situation/Error Cause 1
Situation/Error Cause 2
If the Error Occurs Again
- The milling bur has exceeded its service life "P. 72 "Replacing Milling Burs"
- Hold down the operation button on the built-in panel. This will clear the error.
- Replace the milling bur with a new one.
- Perform collet maintenance. "P. 44 "Collet Maintenance, Cleaning of Dummy Pin, and Checking of Coolant Flow Rate
Situation/Error Cause 2
- The milling conditions are too strict.
- Hold down the operation button on the built-in panel. This will clear the error.
- Review the CAM settings and the shape specified in the CAD data.
If the Error Occurs Again
- The collet has worn out, leading to a decrease in its retention capabilities.
- Replace the collet. "P. 83 "Replacing the Collet"
- Perform automatic correction. "P. 56 "Correcting the Milling Machine"
Modificado
April 30, 2020