Article | Roland
Knowledge Base Article

VersaCAMM VP-300i 30" Eco-Solvent Inkjet Printer/Cutter

Title
VersaWorks Measurement Failed Error Code = - 4087
Symptom
VersaWorks Measurement Failed Error Code = - 4087
Cause
VersaWorks error during linearization
Solution
This error typically occurs when attempting to read Linearization (calibration) charts in the media explorer on VersaWorks.  To resolve this issue, change the englargement in queue A to 110% before printing printing the charts. This error is more common when using the EyeOne device.
Applies To
AJ-1000, AJ-1000i, AJ-740, AJ-740i, FP-740, SC-540, SC-540EX, SC-545EX, SJ-1000, SJ-1045, SJ-540, SJ-540EX, SJ-640EX, SJ-645EX, SJ-740, SJ-740EX, SJ-745EX, SP-300, SP-300V, SP-540V, VP-300, VP-300i, VP-540, VP-540i, XC-540, XC-540MT, XJ-540, XJ-640, XJ-740
Modified
May 16, 2014