Title
[1023-0000] to [1028-0000] [Milling data error. ]
Summary
[1023-0000] to [1028-0000] [Milling data error. ]
Details
[1023-0000] to [1028-0000] [Milling data error. ]

• [1023-0000]: Milling data error. The number of the parameters is incorrect.
• [1024-0000]: Milling data error. The parameter is out of range.
• [1025-0000]: Milling data error. A wrong command is detected.
• [1026-0000]: Milling data error. The address is not defined.
• [1027-0000]: Milling data error. The parameter is not defined.
• [1028-0000]: Milling data error. The operation cannot be executed.

Situation/Error Cause 1
There may be a problem with the milling data received from the computer.

Procedure
1. Click [Cancel].
This will clear the error.
2. Review the CAM settings and the shape specified in the CAD data.
• If there are no problems with the milling data
Restart the computer, and then perform milling again.
 
Situation/Error Cause 2
When using CAM to select the stocker number, the stocker number set as the second or third milling bur in Intelligent Tool Control may have been selected.

When using CAM to select the stocker number, select the stocker number set as the first milling bur in Intelligent Tool Control.

RELATED LINKS
P. 55 Automatically Switching Out the Worn Milling Bur (Intelligent Tool Control)