Article | Roland
Knowledge Base Article

DWX-53DC Dry Dental Milling Machine

Title
DWX-53DC - 1006-02**The % axis position has been shifted
Summary
DWX-53DC - 1006-02**The % axis position has been shifted
Details

1006-02**The % axis position has been shifted.

The name of the axis (X, Y, Z, A, B or a combination of these axes) is displayed for %.

 Situation/Error Cause 1
The motor position may have been lost.
Procedure
  1.  Remove any objects blocking the operation of the machine and any accumulated milling waste.
  2.  Hold down the touch sensor on the built-in panel.
    This will clear the error.
Situation/Error Cause 2
The milling conditions may be excessively strict.
Procedure
  1.  Hold down the touch sensor on the built-in panel.
    This will clear the error.
  2.  Review the CAM settings and the shape specified in the CAD data.
Modified
September 14, 2022
TOP