Article | Roland
Knowledge Base Article

DWX-43W

Title
103B-0000The automatic correction is not yet finished
Summary
103B-0000The automatic correction is not yet finished.
Details
Situation/Error Cause 1
  • Automatic correction has not been performed.
  • Automatic correction was canceled before it could finish.
  • Automatic correction was not performed after updating the firmware to a version that required automatic correction to be performed again.
 
Procedure
  1.  Hold down the operation button on the built-in panel.
    This will clear the error.
  2.  Perform automatic correction.
Situation/Error Cause 2
The versions of VPanel and the machine's firmware may not match.

Download the latest versions of VPanel and the machine's firmware, install these versions, and then perform automatic correction.

 
Modified
March 20, 2025
TOP