Knowledge Base Article
DWX-43W
Title
1023-0000 to 1028-0000 Milling data error
Summary
1023-0000: Milling data error. The number of the parameters is incorrect.
1024-0000: Milling data error. The parameter is out of range or an invalid tool number was specified with the ITC settings.
1025-0000: Milling data error. A wrong command is detected.
1026-0000: Milling data error. The address is not defined.
1027-0000: Milling data error. The parameter is undefined or an invalid tool number was specified with the ITC settings.
1028-0000: Milling data error. The operation cannot be executed.
Details
There may be a problem with the milling data received from the computer. |
Procedure
- Hold down the operation button on the built-in panel.
This will clear the error.
- Review the CAM settings and the shape specified in the CAD data.
-
If there are no problems with the milling data
- Restart the computer, and then perform milling again.
-
When using CAM to select the stocker number, the stocker number set as the second or third milling bur in Intelligent Tool Control may have been selected. |