Article | Roland
Knowledge Base Article

DWX-43W

Title
101D-00**The X milling bur cannot be released.
Summary
X indicates a milling bur stocker number from 1 to 7.
Details

 

Situation/Error Cause 1
The returning of the milling bur failed. The inside of the collet or the ATC magazine might be dirty.
 
Procedure
  1.  Follow the instructions on the VPanel display and remove the milling bur.
  2.  Perform collet maintenance.
  3.  Clean the ATC magazine.
Situation/Error Cause 2

The returning of the milling bur failed. The stocker might be out of position.

 
Procedure
  1.  Follow the instructions on the VPanel display and remove the milling bur.
  2.  Perform automatic correction.
Situation/Error Cause 3

It is possible that the milling bur was not removed from the spindle unit after the instruction to remove the milling bur by following the instructions on the VPanel display.

When cleaning the ATC magazine, be sure to remove the milling bur before beginning work.

 
If the Error Occurs Again

The collet may be deformed. In this case, replace the collet.

Replacing the Collet

 

Modified
March 20, 2025