Summary
"101D-010*" The % milling bur cannot be released. It might be broken from the root.
The milling bur stocker number (1 to 7) is displayed for %.
Details
Situation/Error Cause
Situation/Error Cause 2
If the Error Occurs Again
- The milling bur is broken
- The milling bur has exceeded its service life "P. 72 "Replacing Milling Burs"
- Follow the instructions in the VPanel window to open the collet and remove the milling bur.
- Replace the milling bur with a new one.
- Perform collet maintenance."P. 44 "Collet Maintenance, Cleaning of Dummy Pin, and Checking of Coolant Flow Rate"
- Perform automatic correction."P. 56 "Correcting the Milling Machine"
Situation/Error Cause 2
- The milling conditions are too strict.
- Hold down the operation button on the built-in panel.This will clear the error.
- Review the CAM settings and the shape specified in the CAD data.
If the Error Occurs Again
- The collet is deformed.
- Replace the collet."P. 83 "Replacing the Collet"
- Perform automatic correction."P. 56 "Correcting the Milling Machine"