Base de conocimientos Article
DWX-52D 5-Axis Dental Milling Machine
Cargo
Automatic Correction Fails
Síntoma
Automatic Correction Fails
Solución
Is the automatic correction jig, detection pin, or ATC magazine dirty?
Clean away any grime on the automatic correction jig, the detection pin, and the ATC magazine. These items being dirty due to a buildup of milling waste or the like may impede correct sensor operation, making detection impossible. User's Manual Page 53
Is the automatic correction jig properly attached?
Verify that the automatic correction jig is properly attached. User's Manual Page 52 and Page 54
Is the detection pin properly attached?
Verify that the detection pin is properly attached. Check the position of the milling bur holder on the detection pin.Refer to the "Setup Guide" ("Dimensional Drawings" (Detection Pin Dimensions)).
Clean away any grime on the automatic correction jig, the detection pin, and the ATC magazine. These items being dirty due to a buildup of milling waste or the like may impede correct sensor operation, making detection impossible. User's Manual Page 53
Is the automatic correction jig properly attached?
Verify that the automatic correction jig is properly attached. User's Manual Page 52 and Page 54
Is the detection pin properly attached?
Verify that the detection pin is properly attached. Check the position of the milling bur holder on the detection pin.Refer to the "Setup Guide" ("Dimensional Drawings" (Detection Pin Dimensions)).
Modificado
April 28, 2020