DWX-4W Wet Dental Mill

Cargo
Error Message 101F-0000
Síntoma
The milling bur chucking has slipped out.
Solución
Situation/error cause
  • The milling bur holder might be out of position.
  • The milling bur might have been shortened due to wear.
  • The inside of the collet might be dirty.
Action
  1. Follow the messages displayed in VPanel to forc-ibly release the milling bur.
  2. If the milling bur has been shortened due to wear or if the holder is out of position, replace the milling bur.
  3. The milling conditions may be excessively strict, so review them.
  4. If the error occurs even after you review the milling conditions, perform collet maintenance. Carefully clean the inside of the collet.
Situation/error cause
The collet may have worn out.

Action
If the error occurs again even after you perform the above operations, the collet may have worn out. Replace the collet with a new one. After you replace the collet, correct the milling machine.