103B-0000The automatic correction is not yet finished
Síntoma
103B-0000The automatic correction is not yet finished.
Solución
Situation/Error Cause 1
  • Automatic correction has not been performed.
  • Automatic correction was canceled before it could finish.
  • Automatic correction was not performed after updating the firmware to a version that required automatic correction to be performed again.
 
Procedure
  1.  Hold down the operation button on the built-in panel.
    This will clear the error.
  2.  Perform automatic correction.
Situation/Error Cause 2
The versions of VPanel and the machine's firmware may not match.

Download the latest versions of VPanel and the machine's firmware, install these versions, and then perform automatic correction.

 