Solución
Draining the Coolant Lines
Drain the fluid collected in the coolant lines running through the machine.
Situations Requiring This Work
- When there are no plans to use the machine for 1 week or longer (or when the machine has not been used for 1 week or longer)
- Before moving the machine (especially when there is a risk of coolant spillage)
Required Tools
Draining
Procedure
- If a workpiece or a milling bur is mounted on the machine, remove it.
Important: Do not remove the detection pin.
-
Remove the coolant tank and discard the coolant. Proceed to the next step without returning the coolant tank to its original position.
- Place the tray with the coolant tank inside the bottom cover in the stored position.
- Show VPanel.
- Show VPanel.
- Select a machine to operate.
- Click the radio button to the left of the name of the machine to operate. Click in the top window. The [Settings] screen will appear.
- Click the [Maintenance] tab.
- Click [Drain coolant].
- Click the [Maintenance] tab.
- Click [Drain coolant]
If the coolant tank has been attached, the message shown in the figure to the left will be displayed. Remove the coolant tank, click [OK], and then perform the procedure again from step. 5
Draining of the coolant lines is complete once the message in the figure is displayed. Click [OK].