Base de conocimientos Article
DWX-4 4-Axis Dental Milling Machine
Cargo
"1022-000*" The % milling bur was not found
Síntoma
"1022-000*" The % milling bur was not found.
The milling bur stocker number (1 to 7) is displayed for %�
Solución
Situation/Error Cause 1
Situation/Error Cause 2
Procedure
If the Error Occurs Again
- The milling bur has not been set.
- The milling bur has been set in an incorrect stocker number.
- Set the milling bur in the correct position.
- According to the situation, perform the operations shown below.
- When the error occurred during milling
- Press the operation button on the built-in panel. Milling will resume.
- When the error occurred outside of milling
- Hold down the operation button on the built-in panel. This will clear the error.
- When the error occurred during milling
Situation/Error Cause 2
- The ATC magazine is out of position.
Procedure
- Perform automatic correction. "P. 56 "Correcting the Milling Machine"
If the Error Occurs Again
- The collet may have worn out. Replace the collet "P. 83 "Replacing the Collet"
- If the error occurs again even after you replace the collet, replace the spindle unit. To replace the spindle unit, contact your authorized Roland DGA Corporation
Modificado
April 30, 2020